Click Here for An Immediate Factory Pricing Quote For the TI-80A ▶
Pricing Is Now On Display
Product Overview
These central chiller systems range from
20 to 180 tons of cooling capacity providing a coolant temperature range between 20°F and 80°F when using R410A refrigerant.
The standard Central Chiller is
configured with reservoir and pumps housed in a single frame – making it a complete self-contained package which reduces installation costs compared to other systems.
These central chiller systems are air-cooled requiring an outdoor remote
condenser to reject the heat removed from
the refrigeration circuit.
These central chiller systems can
be configured for future expansion to meet your growing cooling needs with the addition of chiller modules.
The dual pump system features one pump dedicated to distributing coolant through the plant and a second internal re-circulation pump accommodating ever
changing process flow demand.
The standard tank is a patented, one-piece, seamless, non-rusting rotationally molded reservoir made of a linear low density polyethylene and insulated with
dense foam to minimize sweating and maximize system efficiency.
These central chiller systems use a non-ozone depleting refrigerant and are equipped with hermetic scroll
compressors or tandem scroll compressors that utilize rotary technology for smooth, efficient operation.
Price is Loading
Specifications
Model: TI-80A (1)
Refrigerant Zones
Quantity : 2
Compressor
Quantity : 2
Horsepower : 40
Type : Scroll
(2)Total Capacity : 80 tons
Refrigerant
Type : R-410A
Process Pump(3)(4)
Horsepower : 15
GPM : 240
PSI : 70
Evaporator Pump(3)(4)
Horsepower : 5
GPM : 192
Full Load Amperage(5)(6)
230/3/60 : 376.0
460/3/60 : 188.0
575/3/60 : 151.0
Reservoir Capacity
Operating : 1,200 gallons
Holding : 1,475 gallons
Connection Sizes
To Process : 4"
From Process : 4"
Water Make-Up : 1-1/2"
Overflow : 4"
Condesner : "
Dimension
Height : 112"
Width : 136"
Depth : 126"
Weights
(7)Shipping : 6,300 lbs
Operating : 17,300 lbs
Specification Notes:
Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ 115°F condensing temperature. Capacities may be +/5% as reserved by the compressor manufacturer. Capacity multipliers are 50°F - 1.00 ; 40°F - .80 ; 30°F - .60 ; 20°F - .40.
Consult pump curve for exact pump performance.
Selection of optional pumps for higher flow rates will raise the minimum recommended operating temperature when no glycol is used.
Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ " 115°F condensing temperature. Capacities may be +/- 5% as reserved by the compressor manufacturer. Operating at temperatures below 50° will reduce chiller capacity. The minimum recommended operating temperature when no glycol is used is 48°F.
Field charging by user required.
Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring.